# Multi-Can configuration file # # CAMS,poc,TAMS,type,start_date,stop_date,press_param,mfc_param,port_param,int_temp_POC,min_allow_start_press,max_allow_start_press, # min_allow_stop_press,max_allow_stop_press,ideal_flow,allow_flow_error # # Where: # CAMS = the datalogger ID that the data is collected from # poc = which pressure, mfc, and port to use # TAMS = yet another numbering scheme that the lab uses # type = the type of sampler "cs10" or "entech" # start_date = the date (in UTC) that the settings start YYYYMMDDhhmmss # stop_date = the date (in UTC) that the settings stop YYYYMMDDhhmmss (a value of 0 means still active) # press_param = which pressure parameter number to use # mfc_param = which MFC parameter number to use # port_param = which port parameter number to use # int_temp_POC = which internal temperature to use # min_allow_start_press = minimum allowable starting pressure for the canister # max_allow_start_press = maximum allowable starting pressure for the canister # min_allow_stop_press = minimum allowable stop pressure for the canister # max_allow_stop_press = maximum allowable stop pressure for the canister # ideal_press = the ideal stop pressure for the canister # allow_flow_error = allowable flow error (in percent/100) # schedule = when is canister scheduled to run (0 = National schedule; 1 = On Demand; 2 = Daily; 3 = Event) # event triggered runs do not have a pattern -- it's just a single can that starts whenever # start_press_warn = pressure values between this and max_allow_start_press will be flagged on web pages # stop_press_warn = pressure values between this and min_allow_stop_press will be flagged on web pages # # Optional (not yet implemented): # mfc_offset = offset in minutes from can start and stop times that start and stop flow is grabbed # MUST BE an even five-minute increment # start flow = can start + mfc_offset (start flow should be grabbed after run starts) # stop flow = can stop - mfc_offset (stop flow should be grabbed before run stops) # press_offset = offset in minutes from can start and stop times that start and stop press is grabbed # MUST BE an even five-minute increment # start press = can start - press_offset (start press should be grabbed before run starts) # stop press = can stop + press_offset (stop press should be grabbed after run stops) # # # NOTE: the current active definition for each unique CAMS number needs to be the last ordered entry # ### Deleted all non-multican, event triggered or on demand samplers ### ### If there are problems w/ can tracker, revert back to saved file MULTICAN.DAT.123008 ### # ## REG 1 ## 79,1,E079,entech,20030805130000,0,11001,11000,11002,1,-1,.8,7,11.9,11,.15,3,.5,10.5 104,1,E104,entech,20030805130000,20110101000000,11001,11000,11002,1,-1,.8,7,11.9,11,.15,3,.5,10.5 105,1,E105,entech,20030805130000,20110101000000,11001,11000,11002,1,-1,.8,7,11.9,11,.15,3,.5,10.5 105,2,E205,entech,20030805130000,20110101000000,11001,11000,11002,1,-1,.8,7,11.9,11,.15,3,.5,10.5 ## REG 4 ## 56,1,X157,entech,20031013170000,20070601180000,11001,11000,11002,1,-1,.8,7,13.7,12,.15,1,.5,10.5 70,1,X182,entech,20031014180000,20070601180000,11001,11000,11002,1,-1,.8,7,13.7,12,.15,1,.5,10.5 71,1,X071,entech,20040407000000,20070601180000,11001,11000,11002,1,-1,.8,7,13.7,12,.15,1,.5,10.5 89,1,Z400,entech,20100701191500,20110101000000,11001,11000,11002,1,-1,.8,7,13.7,12,.15,1,.5,10.5 94,1,X158,entech,20031014180000,20070601180000,11001,11000,11002,1,-1,.8,7,13.7,12,.15,1,.5,10.5 97,1,Z401,entech,20100714200500,20110101000000,11001,11000,11002,1,-1,.8,7,13.7,12,.15,1,.5,10.5 ## REG 5 ## 85,1,E303,entech,20040120193500,20110101000000,11001,11000,11002,1,-1,.8,7,13.7,12,.15,3,.5,10.5 644,2,E644,entech,20050601000000,2008040200000,11001,11000,11002,2,-1,.8,7,13.7,12,.15,3,.5,10.5 668,1,E668,entech,20060802000000,2006121500000,11001,11000,11002,2,-1,.8,7,13.7,12,.15,3,.5,10.5 ## REG 6 ## 12,1,X151,entech,20031209220000,20110101000000,11001,11000,11002,1,-1,.8,7,11.9,11,.15,1,.5,10.5 37,1,X159,entech,20031210160000,20110101000000,11001,11000,11002,1,-1,.8,7,11.9,11,.15,1,.5,10.5 ## REG 10 ## 665,1,E665,entech,20060726000000,2006111400000,11001,11000,11002,1,-1,.8,7,13.7,12,.15,3,.5,10.5 ## REG 12 ## 8,1,X150,entech,20030709140000,20110101000000,11001,11000,11002,1,-1,.8,7,13.7,12,.15,1,.5,10.5 26,1,X154,entech,20030820124500,20110101000000,11001,11000,11002,1,-1,.8,7,13.7,12,.15,1,.5,10.5 34,1,X152,entech,20030722100000,20070322000000,11001,11000,11002,3,-1,.8,7,13.7,12,.15,1,.5,10.5 #1029,2,E307,entech,20111201000000,20121031235500,11001,11000,11002,1,-1,.8,7,13.7,12,.15,1,.5,10.5 1029,2,E407,entech,20121101010000,0,11001,11000,11002,1,-1,.8,7,13.7,12,.15,3,.5,10.5 1034,1,X183,entech,20070320130000,20110101000000,11001,11000,11002,3,-1,.8,7,13.7,12,.15,1,.5,10.5 #1049,2,E330,entech,20080630000000,20121031000000,11001,11000,11002,1,-1,.8,7,13.7,12,.15,3,.5,10.5 1049,2,E430,entech,20121101000000,0,11001,11000,11002,1,-1,.8,7,13.7,12,.15,3,.5,10.5 ## REG 14 ## 98,1,E155,entech,20040525000000,20110101000000,11001,11000,11002,1,-1,.8,7,13.7,12,.15,3,.5,10.5 168,2,E168,entech,20031118150000,20110101000000,11001,11000,11002,1,-1,.8,7,13.7,12,.15,3,.5,10.5 170,1,E170,entech,20041014211500,20110101000000,11001,11000,11002,1,-1,.8,7,13.7,12,.15,3,.5,10.5 1024,1,E408,entech,20121101010000,0,11001,11000,11002,1,-1,.8,7,13.7,12,.15,3,.5,10.5