Skip to Content

boiler_list.txt

text/plain boiler_list.txt — 6.2 KB

File contents

Texas Natural Resource Conservation Commission recent permit
limits for gas-fired boilers and heaters
(Current as of 6/94)

Units rated 250 MMBtu/hr and greater heat input


    Permit No.   Permit    Company              # of  MMBtu/hr
    TACB   PSD   Issued    Name          Type   Units  /Unit
1.   2165   ---  Pending   Rohm & Haas   Blr      1     623
2.  20365   785  Pending   Temple-Inland Blr      1     337
3.    216   ---  06/20/94  Champion Int. Blr      1     550
4.  22312   831  06/09/94  Citgo         Blr      1     320
5.  22475   833  05/23/94  Inland-Orange Blr      1     420
6.    735B  ---  02/16/94  BASF          Blr      1     325
7.  20040   801  07/07/93  Goodyear      Blr      1     265
8.  20289   ---  02/14/91  EGP Fuels     Htr      1     295 

    NOx     CO ppmvd  Burner    Proposed    Fuel   
    #/MMBtu @3% O2    Mfr/Mod    % FGR      Type     Engr 
1.  ?        ?         ?          ?         ?        JBW
2.  0.06     100       Fost.Whlr. ?         NG       LLP
3.   ?        ?        ?          ?         NG       AML
4.  0.06     100       ?          ?         NG,FG    EOU
5.  0.05     122       ?          ?         NG       EOU
6.  0.06     150       ?          ?         NG/H2    MHK
7.  0.06?    ?         ?          ?         ?        EOU
8.  0.06     65        ?          None      NG,FG    SEA

Units rated less than 250 MMBtu/hr but greater than 100
MMBtu/hr heat input 


    Permit No.   Permit     Company            # of  MMBtu/hr 
    TACB   PSD   Issued      Name       Type   Units  /Unit
1.    216   ---  06/20/94  Champion Int  Blr     2     235   
2.  22039   816  Pending   Crown Central Blr     1     300   
3.  20289   ---  02/14/91  Tenneco NGL   Blr     2     234   
4.  20042   ---  10/26/90  Global Octan  Htr     1     130   
5.  19880   776  10/25/90  Occidental C  Blr     1     245   
6.  20123   ---  10/09/90  Texaco Chem   Blr     2     210   
7.  19681   771  09/06/90  Air Products  Blr     1     210   
8.  19660   769  03/06/90  Simpson Pasa  Blr     2     213   
9.  19623   ---  03/01/90  Champlin Ref  Blr     1     201   

    NOx      CO ppmvd  Burner    Proposed   Fuel    
    #/MMBtu  @3% O2    Mfr/Mod    % FGR     Type     Engr 
1.   0.06      100        ?          ?       NG       AML
2.   0.06      100        ?          ?       50%vH2   LLP
3.   0.08       33        ?      Internal    60%vH2   SEA
4.   0.08       53        ?        None      40%vH2   SEA
5.   0.12      100     Coen/DAF      8%      60%H2    MLC
6.   0.063      44     Coen/DAF      4%      NG       HMC
7.   0.05       60     John Zink    20%      NG/WG    JGL
8.   0.10       50     Coen/DAF    None      NG       JWT
9.   0.12      115        ?        None      RFG      JWT

Units rated less than 100 MMBtu/hr but greater than 40
MMBtu/hr heat input  
(Amd means permit amendment)


    Permit No.  Permit    Company           # of     MMBtu/hr
    TACB        Issued      Name      Type  Units     /Unit  
1.    216  Amd  06/20/94  Champion    Blr     2              
2.  23099  ---  01/20/94  SMU         Blr     1        72    
3.  21411  ---  11/20/92  Alcon Labs  Blr     1        41    
4.  21104  ---  08/26/92  LaGloria    Blr     1        98    
5.  20594  ---  05/14/91  Dixie Chem. Blr     1        73    
6.  20504  ---  03/12/91  U.T. System Blr     2        56    
7.  17543  Amd  02/22/91  Mobil E & P Blr     2        50    
8.   9092  Amd  02/18/91  Kaneka      Blr     1        66    
9.   9347  Amd  01/17/91  Shintech    Blr     2        73    
10. 20131  ---  10/05/90  Am. Airline Blr     4        70   

    NOx      CO ppmvd   Burner    Proposed   Fuel   
    #/MMBtu   @3% O2    Mfr/Mod     % FGR    Type     Engr 
1.                                           NG       AML
2.  0.06      200       C-B         ?        NG       EHH
3.  0.06      100       Johnston    ?        NG,FO    EOU
4.  0.08      100       Holman    Internal   NG,RFG   JGL
5.  0.06      165       Coen        8        NG       JWT
6.  0.06      207       Coen        8        NG       HMC
7.  0.06       15       N.A.4131   10        NG       DRF
8.  0.05       55       B&W       10-15      NG,WG    JGL
9.  0.06      215       Coen        7        NG,WG    HMC 
10. 0.06      200       Coen       20        NG       JWT

Units rated less than 40 MMBtu/hr heat input (normally meet
standard exemption 7)


    Permit No.  Permit     Company             # of   MMBtu/hr
    TACB   PSD  Received    Name       Type    Units    /Unit 
1.  19910  ---  01/08/90  J. Petersmit  Blr      1       27  
2.  19920  ---  01/16/90  Har. Meth.    Blr      1       30  
3.  20042  ---  03/28/90  Global Octan  Blr      1       33  

    NOx    CO ppmvd   Burner     Proposed   Fuel   
    #/MMBtu  @3% O2    Mfr        % FGR     Type      Engr 
1.  0.10     20 est               None      NG/FO      JGL
2.  0.10       ?        ?         None      NG         JWT
3.  0.08       ?        ?         None      NG,50%H2   SEA   


Permitted chemical sources with or without combustion sources
using selective catalytic reduction (SCR).  Gas turbines are
on a separate list.

    Permit No.   Permit    Company          # of       % NOx
    TACB   PSD   Issued    Name             Units      Reduced
1.  9468   ---   08/24/84  DuPont             1          76  
    Description:  Nitric Acid Production Unit.

2.  1295   ---   03/31/89  Mobil Chemical     1           ? 
    Description:  Catalyst Production Unit - calciners.

3.  19169  ---   08/09/90  Occidental Chem.   4           ? 
    Description:  Four 65 MMBtu/hr ethylene dichloride
    cracking furnaces are vented through 1 SCR/heat recovery
    steam generation.

4.  20042  ---   10/26/90  Global Octanes     1          90 
    Description:  Methyl-tertiary-butyl-ether catalyst
    regeneration unit with heat recovery steam generation.

5.  21770  ---   12/03/92  Clean Fuels        2           ?  
    Description:  Two 283 MMBtu/hr boilers at a
    methyl-tertiary-butyl ether plant.

    NOx        NOx ppmvd    NH3 ppmvd      Fuel   
    #/MMBtu      @ % O2      @ % O2        Type     Engr 
1.    ---         170       <5 (meas.)      ---     LRR
2.    ---          ?         ?              NG      FBC
3.    0.02         12       10              NG      WSW
4.      ?          ?         8              NG      SEA
5.    0.02         ?        10              NG      HDP